AXIOM BOINC SESSION RESULTS Timestamp: 2026-03-04 (CET) Session Scope: Validation/Credit/Cleanup + Deployment/Experiment Design Summary RESULTS REVIEWED AND CREDIT AWARDED - Reviewed latest uncredited completed-success result IDs in this validation pass: 1662293, 1666451, 1666858, 1666859, 1666861. - Trusted sanitized payload check (`/opt/axiom/experiment_results/sanitized/`): no matching `{result_name}_safe.json` for reviewed IDs at review time. - Credit outcome for this session: 0 results credited, total credit added 0 (safety cap respected). - Incremental credit SQL updates applied: none (no eligible trusted numeric payloads available at validation time). STUCK/BROKEN TASK CLEANUP - Broken-family active-abort cleanup query executed for: `exp_oscillatory_roughchannel_lbm_resonance%`, `exp_abx_cycle%`; rows changed: 0. - Dead-host stuck cleanup (>12h running and >6h host-silent): rows changed 0. - Hard-ceiling cleanup (>48h running): rows changed 0. - Historical failure watchlist remains unchanged: - `abx_cycle`: 0 success / 66 failed - `oscillatory_roughchannel_lbm_resonance`: 0 / 214 - `potts_pulse_anneal_resonance`: 0 / 15 - `spatial_pgg_delay_fatigue`: 0 / 20 - No active unsent/in-progress backlog remained for those broken families at end-of-check. DEPLOYMENT AND NEW EXPERIMENT DESIGN (PART 2 CONTEXT) - Backlog gate passed before deployment (`unsent + in_progress < 5000`). - CPU deployment: 3414 new CPU WUs created (appid=1), with RAM>=6GB host filter and queue-target logic. - GPU deployment: 307 new GPU WUs created (appid=2) using GPU-aware scripts; transitioner passes executed. - New experiment deployed for first-pass sampling: `xy_delay_thermostat_reentrance.py` (115 targeted CPU WUs). NEW EXPERIMENT NOVELTY CHECK DOCUMENTATION - Candidate: `xy_delay_thermostat_reentrance` (2D XY lattice with delayed adaptive thermostat feedback). - Query: "2D XY model delayed feedback temperature control magnetization study" Result: no direct prior publication found for this exact delayed-thermostat XY setup. - Query: "feedback Ising model 2025 arxiv" Result: related Ising-feedback work exists, but model/control differ from continuous-spin XY delayed thermostat protocol. - Query: "time-delayed XY model lattice" Result: no clear exact-match study for re-entrant delay window under adaptive cooling feedback. - Novelty retained: tests re-entrant control benefit at intermediate delay versus near-zero and large-delay regimes. KEY SCIENTIFIC FINDINGS 1. No new cross-validated result reached the 30+ seed promotion threshold in this validation window; confirmed findings list remains unchanged. 2. Trusted sanitized-result lag is still the primary blocker for quality-based credit assignment on newly completed rows. 3. Four high-failure experiment families remain retired candidates with no active backlog at close of session (`abx_cycle`, `oscillatory_roughchannel_lbm_resonance`, `potts_pulse_anneal_resonance`, `spatial_pgg_delay_fatigue`). 4. New `xy_delay_thermostat_reentrance` deployment establishes a novel delayed-feedback XY control test for potential re-entrant ordering behavior. POINT-IN-TIME SNAPSHOT (validation log reference) - success_total (`server_state=5,outcome=1,name like exp_%`): 918 - success_credited (`granted_credit>0`): 884 - success_uncredited (`granted_credit=0`): 34 - website counters at log time: credited_count=7218, total_results_count=889